ORIGINAL PAPER
Effectiveness and safety of pneumothorax management in newborns without chest-tube insertion
 
More details
Hide details
1
Department of Paediatrics No. 2, Danylo Halytsky Lviv National Medical University, Lviv, Ukraine
 
 
Submission date: 2019-04-30
 
 
Final revision date: 2019-06-01
 
 
Acceptance date: 2019-06-08
 
 
Publication date: 2019-08-30
 
 
Pediatr Pol 2019;94(4):215-220
 
KEYWORDS
TOPICS
ABSTRACT
Introduction:
Pneumothorax is a serious complication associated with increased morbidity and mortality in newborns. However, chest-tube insertion, which is recommended for treatment of this pathology, is an invasive procedure, which can also lead to adverse clinical consequences.

Aim of the study:
The aim of this study was to identify clinical features of infants with pneumothorax treated without chest-tube insertion.

Material and methods:
In this case series study we report the clinical characteristics and outcomes in 31 outborn infants with pneumothorax, who were successfully managed without chest-tube insertion.

Results:
Pneumothorax occurred at the median age of 2 (range: 0–4) days. Ten (32%) infants had a tension pneumothorax, and in five (16%) cases bilateral pneumothorax was observed. Mean birth weight of the newborns was 2287.42 ±755.45 γ and gestational age – 34.29 ±3.2 weeks. The majority of infants were late preterm (77%). Surfactant therapy was used in 23% of all cases. All infants had an underlying primary lung disease. Twenty-three (74%) infants were on non-invasive respiratory support at the time of pneumothorax occurrence, and 18 (78%) of them were switched to mechanical ventilation (MV) as soon as the diagnosis was confirmed. CPAP was the most commonly used type of initial respiratory support. The majority of infants did not need high ventilatory settings at the moment of pneumothorax occurrence. Needle aspiration was performed in 11 (35%) cases: in all 10 infants with tension pneumothorax and in one case of non-tension pneumothorax. Twenty (65%) infants were managed expectantly. High-frequency oscillatory ventilation (HFOV) was used in 13 cases – 50% of infants who were on MV. In total, 26 newborns with pneumothorax were successfully cared for on MV without chest tube placement.

Conclusions:
A selected group of haemodynamically stable mechanically ventilated neonates with pneumothorax could be successfully treated without chest-tube insertion.
REFERENCES (17)
1.
Kitsommart R, Martins B, Bottino MN, Sant’Anna GM. Expectant management of pneumothorax in preterm infants receiving assisted ventilation: report of 4 cases and review of the literature. Respir Care 2012; 57: 789-793.
 
2.
Duonga HH, Mireab L, Shahb PS, et al. Pneumothorax in neonates: trends, predictors and outcomes. J Neonatal Perinatal Med 2014; 7: 29-38.
 
3.
Kitsommart R, Janes M, Mahajan V, et al. Outcomes of late-preterm infants: a retrospective, single-center, Canadian study. Clin Pediatr 2009; 48: 844-850.
 
4.
Bhatia R, Davis PG, Doyle LW. Identification of pneumothorax in very preterm infants. J Pediatr 2011; 159: 115-120.
 
5.
Litmanovitz I, Carlo WA. Expectant management of pneumothorax in ventilated neonates. Pediatrics 2008; 122: 975-979.
 
6.
Aurilia C, Ricci C, Tana M, et al. Management of pneumothorax in hemodynamically stable preterm infants using high frequency oscillatory ventilation: report of five cases. Ital J Pediatr 2017; 43: 114-119.
 
7.
Smith J, Schumacher RE, Donn SM, et al. Clinical course of symptomatic spontaneous pneumothorax in term and late preterm newborns: report from large cohort. Am J Perinatol 2011; 28: 163-167.
 
8.
Brooker RW, Booth GR, DeMelto DE, et al. Unsuspected transaction of lung by pigtail catheter in a premature infant. J Perinatol 2007; 27: 190-192.
 
9.
Fraser RS. Lung perforation complicating tube thoracostomy: pathologic description of three cases. Hum Pathol 1988; 19: 518-523.
 
10.
Arya H, William J, Ponsford SN, et al. Neonatal diaphragmatic paralysis caused by chest drains. Arch Dis Child 1991; 66: 441-442.
 
11.
Odita JC, Khan AS, Dincsoy M. Neonatal phrenic nerve paralysis resulting from intercostal drainage of pneumothorax. Pediatr Radiol 1992; 22: 379-381.
 
12.
Kumar SP, Belik J. Chylothorax: a complication of chest tube placement in a neonate. Crit Care Med 1984; 12: 411-412.
 
13.
Quak J, Szatmari A, van den Anker J. Cardiac tamponade in a preterm neonate secondary to a chest tube. Acta Paediatr 1993; 82: 490-491.
 
14.
Walker MW, Shoemaker M, Riddle K, et al. Clinical process improvement: reduction of pneumothorax and mortality in high-risk preterm infants. J Perinatol 2002; 22: 641-645.
 
15.
Ellsbury DL, Klein JM, Segar JL. Optimization of high-frequency oscillatory ventilation for the treatment of experimental pneumothorax. Crit Care Med 2002; 30: 1131-1135.
 
16.
Gonzalez F, Harris T, Black P, et al. Decreased gas flow through pneumothoraces in neonates receiving high-frequency jet versus conventional ventilation. J Paediatr 1987; 110: 464-466.
 
17.
Chen D, Huang XL, Li XP. Clinical application of high-frequency oscillatory ventilation for the treatment of neonatal pneumothorax. Chin J Contemp Pediatr 2012; 14: 499-501.
 
Journals System - logo
Scroll to top